Description
DESCRIPTION
The HAMILTON-T1 is the first transport ventilator that combines the functionality of a fully featured ICU ventilator with the compactness and ruggedness required for transport. This combination enables you to provide optimal ventilation therapy to all patient groups during transport. – Approvals and certificates for use in ambulances, helicopters and airplanes – Adult, pediatric, and neonatal ventilation – Independence from compressed air – Up to 9 hours of battery operating time – Noninvasive ventilation and integrated high flow oxygen therapy – Advanced ventilation modes, including ASV® and INTELLiVENT®-ASV – CPR ventilation – Digital solutions for respiratory care: Hamilton Connect Module and App The most popular ventilator for intensive care transport helicopters According to the HOVER survey (Handover of ventilated Helicopter Emergency Services [HEMS] patients in the emergency room) conducted online amongst air rescue organizations in Germany, Austria, Switzerland, Italy, and Luxemburg, 71% of those organizations chose the HAMILTON-T1 as their intensive care transport ventilator (1). Designed for mobility and convenient transport Approved for all types of transport The HAMILTON-T1 meets the transport standards EN 794-3 and ISO 10651-3 for emergency and transport ventilators, EN 1789 for ambulances, EN 13718-1 and RTCA/DO-160G for aircraft, as well as IEC 60601-1-12 for basic safety and essential performance. It reliably accompanies your patients to any destination either within or outside of the hospital, on the ground, at sea, and in the air.
Hamilton T1 Transport Ventilator is the first transport ventilator that combines the functionality of a fully-featured ICU ventilator with the compactness and ruggedness required for transport.
Features of Hamilton C6 ICU Ventilator:
- Oxygen adjustable from 21 % to 100 %
- High-performance noninvasive ventilation (NIV)
- INTELLiVENT-ASV
- CPR ventilation
- Hamilton Connect Module
- Hamilton Connect App
- High flow oxygen therapy
- Adult, pediatric, and neonatal ventilation
- Approved for all types of transport
- Hot-swappable battery backup
- Mobility for primary, secondary, and intra-hospital transport
- Integrated high-performance turbine
- Use with night vision goggles
- Adaptive Support Ventilation (ASV)
- All ventilation modes
- Volumetric capnography
- Leak compensation for NIV and invasive ventilation
- nCPAP modes
- Dynamic Lung for simplified patient monitoring
- Vent Status for weaning assessment
- Proximal flow sensor for precise measurements
- SpO2 measurement
- Configurable loops and trends
- Optimal alarm detection
- Integrated pneumatic nebulizer
- Speaking valve
- Serial interface for connection to PDMS or patient monitors
- Remote access to humidifier controls and status
Specification of Hamilton T1 Transport Ventilator:
Brand | Hamilton |
Model | T1 |
Patient Age Group | Paediatric, Adult, and Neonatal |
Tidal Volume | Adult/Ped: 20 to 2000 ml, Neonatal: 2 to 300 ml |
Ventilation Mode | APVcmv/(S)CMV+, APVsimv/SIMV+, PCV+, PSIMV+, DuoPAP, APRV, SPONT, ASV, NIV, NIV-ST, nCPAP, nCPAP-PC, HiFlowO2 |
Maximum Inspiratory Flow | 260 L/min (120 L/min with 100% O2) |
Oxygen Percentage | Adult/Ped: 21 to 100, Neonatal: 21 to 100 |
Flow Trigger | Adult/Ped: 1 to 20 L/min, Neonatal: 0.1 to 5 L/min |
Electromagnetic Compatibility | According IEC 60601-2:2014 |
Oxygen Pressure | High Pressure: 2.8 to 6 bar / 41 to 87 psi, Low Pressure: Maximum 6 bar / 87 psi |
Oxygen Connector | High Pressure: DISS (CGA 1240) or NIST, Low Pressure: Quick-coupling system, compatible with Colder Products Company (CPC) PMC series |
Air Supply | Integrated turbine |
Battery Backup | Typically 4 hours with one battery, 8 hours with two batteries |
Weight | 6.5 kg (14.3 lb), 18.5 kg (40.8 lb) with trolley |
There are no reviews yet.